Metering & Transformers
Austin Energy Approved Equipment
Specifications for electric meter and transformer types by manufacturer are provided below.
General Information
- Guidelines for Instrument Rated Metering and Checklist for Electrical Contractors (pdf)
- Voltage Transformer (VT) Enclosure Information (pdf)
- Service and Equipment Information (pdf)
- Small Load vs Large Load Description (pdf)
- Small Load vs Large Load Metered Services NOT Metered at Padmount Transformer (pdf)
Metering Equipment
-
Approved Metering Equipment for Services Metered at the Transformer
120-208 Volt Three Phase WYE Padmount Metered Instrument Rated Service
- Large Load 120-208 Volt Padmount Metered IR Service 225 Amps to 1200 Amps (pdf)
- Large Load 120-208 Volt Padmount Metered IR Service 1201 Amps to 3500 Amps (pdf)
- Large Load 120-208 Volt Padmount Metered IR Service 3501 Amps to 4000 Amps (pdf)
120-240 Volt Three Phase Delta Padmount Metered Instrument Rated Service
- Large Load 120-240 Volt Padmount Metered IR Service 225 Amps to 1200 Amps (pdf)
- Large Load 120-240 Volt Padmount Metered IR Service 1201 Amps to 3000 Amps (pdf)
- Large Load 120-240 Volt Padmount Metered IR Service 3001 Amps to 4000 Amps (pdf)
277-480 Volt Three Phase WYE Padmount Metered Instrument Rated Service
- Large Load 277-480 Volt_Padmount Metered IR Service 226 Amps to 1200 Amps (pdf)
- Large Load 277-480 Volt_Padmount Metered IR Service 1201 Amps to 3000 Amps (pdf)
- Large Load 277-480 Volt_Padmount Metered IR Service 3001 Amps to 4000 Amps (pdf)
-
Approved Metering Equipment for Services Not Metered at the Transformer
120-240 Volt Single Phase
- Small Load 120-240 Volt Single Phase 200 Amp Self-Contained Services (pdf)
- Small Load 120-240 Volt Single Phase 320 Amp Self-Contained Services (pdf)
- Large Load 120-240 Volt Single Phase Instrument Rated Services 351 to 600 Amps Amps (pdf)
- Large Load 120-240 Volt Single Phase Instrument Rated Services 601 to 1200 Amps Amps (pdf)
- Large Load 120-240 Volt Single Phase Instrument Rated Services 1201 Amps to 1600 Amps (pdf)
- Large Load 120-240 Volt Single Phase Instrument Rated Services 1601 Amps to 2000 Amps (pdf)
- Large Load 120-240 Volt Single Phase Instrument Rated Services 2001 Amps to 3500 Amps (pdf)
120-208 Volt Single Phase
- Small Load 120-208 Volt Single Phase Self Contained Services (pdf)
- Large Load 120-208 Volt Single Phase and 480 Volt Three Wire Three Phase IR Service up to 600 Amps (pdf)
- Large Load 120-208 Volt Single Phase and 480 Volt Three Wire Three Phase IR Service 601 Amps to 1200 Amps (pdf)
- Large Load 120-208 Volt Single Phase and 480 Volt Three Wire Three Phase IR Service 1201 Amps to 1600 Amps (pdf)
- Large Load 120-208 Volt Single Phase and 480 Volt Three Wire Three Phase IR Service 1601 Amps to 2000 Amps (pdf)
- Large Load 120-208 Volt Single Phase and 480 Volt Three Wire Three Phase IR Service 2001 Amps to 3500 Amps (pdf)
120-208 Volt Three Phase WYE
- Small Load 120-208 Volt Three Phase WYE Self Contained Services (pdf)
- Large Load 120-208 Volt Single Phase Instrument Rated Services 351 Amps to 600 Amps (pdf)
- Large Load 120-208 Volt Three Phase WYE Instrument Rated Services 601 Amps to 1200 Amps (pdf)
- Large Load 120-208 Volt Three Phase WYE Instrument Rated Services 1201 Amps to 1600 Amps (pdf)
- Large Load 120-208 Volt Three Phase WYE Instrument Rated Services 1601 Amps to 2000 Amps (pdf)
- Large Load 120-208 Volt Three Phase WYE Instrument Rated Services 2001 Amps to 3500 Amps (pdf)
120-240 Volt Three Phase Delta
- Small Load 120-240 Volt Three Phase Delta Self Contained Services (pdf)
- Large Load 120-240 Volt Three Phase Delta Instrument Rated Services 351 Amps to 600 Amps (pdf)
- Large Load 120-240 Volt Three Phase Delta Instrument Rated Services 601 Amps to 1200 Amps (pdf)
- Large Load 120-240 Volt Three Phase Delta Instrument Rated Services 1201 Amps to 1600 Amps (pdf)
- Large Load 120-240 Volt Three Phase Delta Instrument Rated Services 1601 Amps to 2000 Amps (pdf)
- Large Load 120-240 Volt Three Phase Delta Instrument Rated Services 2001 Amps to 3500 Amps (pdf)
277-480 Volt Three Phase WYE
- Small Load 277-480 Volt Three Phase WYE Self Contained Services (pdf)
- Large Load 277-480 Volt Three Phase WYE Instrument Rated Services up to 600 Amps (pdf)
- Large Load 277-480 Volt Three Phase WYE Instrument Rated Services 601 Amps to 1200 Amps (pdf)
- Large Load 277-480 Volt Three Phase WYE Instrument Rated Services 1201 Amps to 1600 Amps (pdf)
- Large Load 277-480 Volt Three Phase WYE Instrument Rated Services 1601 Amps to 2000 Amps (pdf)
- Large Load 277-480 Volt Three Phase WYE Instrument Rated Services 2001 Amps to 3500 Amps (pdf)
-
Meter Socket Specifications for Manufacturers
- E-1001 200 Amp Single Phase Meter Socket (pdf)
- E-1002 Seven Terminal 200 Amp Three Phase Meter Socket (pdf)
- E-1045 Single Phase Meter Socket Class 320 (pdf)
- E-1565 Six Terminal IR Single Phase Socket Prewire Ts (pdf)
- E-1566 Three Terminal IR Three Phase Socket Prewire Ts (pdf)
- E-1567 Thirteen Terminal IR Three Phase Socket Prewire Ts and VT pack (pdf)
-
Primary Metering Specifications and Approved Metering Equipment
Primary Metering Specifications
- Primary Metering - 150 Amps (pdf)
- Primary Metering - 600 Amps (pdf)
- Primary Metering - 900 Amps (pdf)
Primary Metering Equipment
-
Meter Hubs
Specifications and approved manufacturers for customer-provided meter hubs are provided below.
Hub Description Approved Manufacturers Hub, meter base socket 1 Durham ARP00003
Milbank A7514
Hub, meter base socket 1 ¼ inch Durham ARP00004
Milbank A7515
Hub, meter base socket 1 ½ inch Durham ARP00005
Milbank A7516
Hub, meter base socket 2 inch Durham ARP00006
Milbank A7517
Hub, meter base socket 2 ½ inch Durham ARP00007
Milbank A7518
Hub, meter base socket 3 inch Durham ARP00019
Milbank A8110
Removable hub, meter base closing plate
standard 3 inchDurham ARP00002
Milbank A7551
Removable hub, meter closing plate large 4 inch Durham ARP00016
Milbank A9064
-
Modular Metering: Meter pak equipment and modular metering equipment
Modular Metering Equipment in accordance with AE Specification E-1589 (pdf)
Customer must provide the following:
- Modular Metering Request Form (pdf)
- Highlighted Equipment Cut Sheets
- Approved ESPA(s)
- Electrical Riser Diagram/ One-Line
- Site Plan
Customer must obtain written approval from Austin Energy Advanced Metering Systems & Engineering prior to procurement.
New orders for ALL metering equipment have extremely long lead times according to the manufacturers and vendors. This is due to labor and material shortages that have affected production efforts nationwide. It is highly recommended to place your orders for ALL the necessary metering equipment as soon as possible.
Transformers
-
Current Transformers Requirements and Specifications
The customer must supply current transformers when the service is metered at the transformer and when the transformer is installed in an enclosure. Contact Austin Energy Metering for verification at 512-505-7045.
Current Transformer Description Possible window type current transformer ratios: - 600/5 with rating factor 2.0(min) at 55 degree C
- 2000/5 with rating factor 1.5(min) at 55 degree C
- 4000/5 with rating factor 1.0(min) at 55 degree C
Requirements for 5th Terminal Lugs in Meter Socket
- Services that require the voltage of 120/208 Single Phase must have a 5th terminal lug installed in the 9 o’clock position.
- Services that require the voltage of 125/216 single phase must have a 5th terminal lug installed in the 9 o’clock position in the metering socket.
- The 5th terminal lug is purchased in addition to the socket being purchased. It is only required for single phase
120/208 and 125/216
volt services. - Meter sockets requiring the 5th lug terminal must be identical to the sockets specified with the exception that it has the 5th lug terminal installed.
-
Distribution Transformer Fault Current Tables Reference Guide
For transformers in the downtown Network area contact a Network Design representative to obtain the fault current.
Customers should be advised that the fault current calculations were performed using infinite bus at the transformer secondary terminals.
Note: Austin Energy reserves the right to make system modifications including feed changes and transformer upgrades to maintain service without customer notification. System modifications can result in higher fault currents.
Transformer Size/Type Fault Current (amperes) 120/240 volt single-phase 120/208 volt three-phase 277/480 volt three-phase Single-Phase Transformers 1-10 kVA/1-ph 2778 n/a n/a 1-25 kVA/1-ph 6944 n/a n/a 1-50 kVA/1-ph 13889 n/a n/a 1-75 kVA/1-ph 20833 n/a n/a 1-100 kVA/1-ph 27778 n/a n/a 1-167 kVA/1-ph 43490 n/a n/a Three-Phase Transformers 75 kVA n/a 11566 5011 150 kVA n/a 23132 10024 225 kVA n/a 34698 15036 300 kVA n/a 46263 20047 500 kVA n/a 77106 33412 750 kVA n/a 39280 17021 1000 kVA n/a 52374 22695 1500 kVA n/a n/a 34043 2000 kVA n/a n/a 45391 2500 kVA n/a n/a 56738 Questions or Feedback?
Customer-Provided Metering and Transformer Hardware
-
Specifications and Approved Manufacturers
Specifications and approved manufacturers for customer-provided metering and transformer hardware are provided below.
Hardware Description Approved Manufacturers Bolts. Machine. ½ inch x 4 inch, square head, rolled threads, hot dip galvanized, furnished with one square nut assembled.
AB Chance 8706
MPS J8706
Bolts. Machine. ½ inch x 6 inch, square head, rolled threads, hot dip galvanized, furnished with one square nut assembled.
AB Chance 8706
MPS J8706
Bolts. Machine. ½ inch x 8 inch, square head, rolled threads, hot dip galvanized, furnished with one square nut assembled.
AB Chance 8708
MPS J8708
Bolts, Machine. ½ inch x 12 inch, square head, rolled threads, hot dip galvanized, furnished with one square nut assembled.
AB Chance 8712
MPS J8712
Washer. ½ inch, round, hot dip galvanized.
AB Chance 6803
Maclean J1086
Rack. Pulley type, 1 point less insulator with 11/16 inch bold, 90 degree slot in bracket case.
AB Chance C207-0072
Maclean J-252
Insulator. Spool type, polymer, 3 inch length, 30 1/8 inch diameter, 11/16 inch grove radius.
11/16 inch hole diameter in accordance with EEI Class 53-2.
Must meet ANSI C29.3-1986 SEC 8.2.1, ANSI C29.1-1982 SEC 4.2 & 4.3, ANSI C29.1 SEC 5.1.6-1988, and ANSI C29.3 SEC 8.3.3-1986
HPS C909-1032P
Insulator. Wireholder service mast. Pipe Size 1 ¼ inch to 2 ½ inch reinforced, gray porcelain, insulator with full metal base or nylon composite, with 7/8 inch hole, rigid assembly.
HPS C2070144
MPS JO588Z
Power DW2C5
Insulator. Wireholder service mast. Pipe size 3 inch to 4 inch reinforced, gray porcelain, insulator with full metal base or nylon composite, with 7/8 inch hole, rigid assembly.
AB Chance C207-0076